| Frequency range | 19.440MHz - 700.000MHz | |
| Temperature Stability | Choose from available options | |
| VDD Sensitivity | ||
| Operating Temperature Range | Choose from available options | |
| Storage Temperature Range | -55°C to +125°C | |
| Supply Voltage (VDD) | ±5% | 2.5VDC |
| Supply Current | 19.440MHz to 160.000MHz 160.001MHz to 700.000MHz | 50mA Maximum 65mA Maximum |
| Warm-up Time | ||
| Power Consumption | ||
| Output Voltage HCMOS | ||
| Output Voltage Logic High (VOH) | 1.43VDC Typical, 1.6VDC Maximum | |
| Output Voltage Logic Low (VOL) | 1.1VDC Typical, 0.9VDC Minimum | |
| Duty Cycle | 50% of waveform | 40% / 60% Max or 45% / 55% Max |
| Load Drive Capability | 100 Ohms | |
| Rise/Fall Time | at 20% to 80% waveform | 1nSec Maximum |
| Control Voltage Range | 1.25VDC ±1.00VDC | |
| Transfer Function | Positive Transfer Characteristic | |
| Input Impedance | ||
| Linearity | 5% to 20% | Choose from available options |
| Pullability | ±50ppm to ±150ppm | Choose from available options |
| Output Type | LVDS | |
| Output Voltage | ||
| Start Up Time | 10mSeconds Maximum | |
| Standby Current | ||
| RMS Phase Jitter | 12KHZ to 20MHz offset freq | 0.4pSec Typical, 1pSec Maximum |
| Phase Noise | at 156.250MHz | -60dBc/Hz at 10Hz Offset -95dBc/Hz at 100Hz Offset -125dBc/Hz at 1kHz Offset -143dBc/Hz at 10kHz Offset -145dBc/Hz at 100kHz Offset -145dBc/Hz at 1MHz Offset -146dBc/Hz at 10MHz Offset |
| Tristate Function | VIH = 70% of VDD min to Enable Output VIL = 30% max or grounded to Disable Output (High Impedance |
|
| Pad 1 Connection | ||
| Mechanical Trim | ||
| Aging | ||
| Tune Port Input Impedance | 50kOhms Minimum | |
| Tune Port Input Modulation Bandwidth | 25kHz Minimum | |
| Differential Output (VOD) | 250mV Minimum, 450mV Maximum | |
| Output Offset Voltage (VOS) | 1.125V Minimum, 1.250V Typical, 1.375V Maximum | |
| Differential Output Error (dVOS) | 50mV Maximum | |
| Crystal Cut |
| Fine Leak Test | MIL-STD-883, Method 1014, Condition A |
| Gross Leak Test | MIL-STD-883, Method 1014, Condition C |
| Mechanical Shock | MIL-STD-883, Method 1004 |
| Flammability | UL94-V0 |
| Moisture Resistance | MIL-STD-883, Method 1004 |
| Moisture Sensitivity | J-STD-020, MSL 1 |
| Resistance to Soldering Heat | MIL-STD-202, Method 210, Condition K |
| Resistance to Solvents | MIL-STD-202, Method 215 |
| Solderability | MIL-STD-883, Method 2003 |
| ESD Susceptibility | MIL-STD-883, Method 3015, Class 1, HBM: 1500V |
| Temperature Cycling | MIL-STD-883, Method 1010, Condition B |
| Vibration | MIL-STD-883, Method 2007, Condition A |
| Soldering Temp | |
| Hermeticity of Seal |
Option 1: You can create additional Part Numbers using the Part Number Constructor form. Once a Part Number is created, it can then be added to your quote request by clicking the “Add to Quote” button. You may use this form as many times as needed and each submission will be saved to your quote.
Option 2: If you already know your Part Numbers, you may add them using the Add to Quote by Part Number simplified form.
Receive periodic information about pricing, availability, and product innovation.
We won’t mail you often and we never share your information with others parties.